Saw, S. H. and Akel, M. and Lee, P. C. K. and Ong, S. T. and Mohamad, S. N. and Ismail, F. D. and Nawi, N. D. and Devi, K. and Sabri, R. M. and Baijan, A. H. and Ali, J. and Lee, S. (2012) Magnetic probe measurements in INTI plasma focus to determine dependence of axial speed with pressure in neon. Journal of Fusion Energy, 31 (5). pp. 411-417. ISSN 1572-9591
|
Text
15_ft.pdf Download (2MB) | Preview |
Abstract
Current sheath dynamics generated in INTI plasma focus device operated with neon gas has been studied. A 3-turn Rogowski coil design has been used to measure derivative current. A new magnetic probe was designed and used to study of current sheath arrival time, current profile and velocity variation in the axial phase at different experimental conditions. The current sheath’s average velocity was found to vary with pressure−0.51 with a R2 value of 0.9 which agrees well with the theoretically expected variation of pressure−0.5.
Item Type: | Article |
---|---|
Uncontrolled Keywords: | INTI plasma focus device Current sheath Magnetic probe Neon gas |
Subjects: | Q Science > QC Physics |
Divisions: | Centre for Plasma Research |
Depositing User: | Unnamed user with email masilah.mansor@newinti.edu.my |
Date Deposited: | 28 Mar 2016 08:08 |
Last Modified: | 06 Apr 2016 10:12 |
URI: | http://eprints.intimal.edu.my/id/eprint/132 |